中文核心期刊

中国科技核心期刊

CSCD来源期刊

DOAJ 收录

Scopus 收录

贾静, 杨志鹏. 吹扫捕集-气相色谱/质谱法测定地下水中1,4-二噁烷[J]. 岩矿测试, 2014, 33(4): 556-560.
引用本文: 贾静, 杨志鹏. 吹扫捕集-气相色谱/质谱法测定地下水中1,4-二噁烷[J]. 岩矿测试, 2014, 33(4): 556-560.
Jing JIA, Zhi-peng YANG. Determination of 1,4-dioxane in Groundwater by Purge and Trap-Gas Chromatography/Mass Spectrometry[J]. Rock and Mineral Analysis, 2014, 33(4): 556-560.
Citation: Jing JIA, Zhi-peng YANG. Determination of 1,4-dioxane in Groundwater by Purge and Trap-Gas Chromatography/Mass Spectrometry[J]. Rock and Mineral Analysis, 2014, 33(4): 556-560.

吹扫捕集-气相色谱/质谱法测定地下水中1,4-二噁烷

Determination of 1,4-dioxane in Groundwater by Purge and Trap-Gas Chromatography/Mass Spectrometry

  • 摘要: 1,4-二噁烷有毒,极易进入生态系统对人体及环境造成危害,在自然环境中对水的亲和性较强,且不易为生物所降解,是地下水中一种新型有机污染物,已被世界卫生组织(WHO)定为一种受控物质。但仅有少数国家对地下水中1,4-二噁烷含量作出限量规定,如日本为50 μg/L;我国在此方面尚未作出规定,有关检测方法也未见文献报道。吹扫捕集-气相色谱-质谱法(P&T-GC/MS)具有分析快捷、方法简便、检出限低等优点,近年来被广泛应用于水样分析,本文应用该方法测定地下水中的痕量1,4-二噁烷。通过添加硫酸铵作为样品保护剂,提高了样品的保存时间及防止样品因微生物降解等因素产生变质的问题,同时改善了1,4-二噁烷吹扫脱附效果,仪器响应值提升了1倍。在优化的实验条件下,方法精密度为5.9%~6.6%;检出限为1.02 μg/L,已经达到了WHO饮用水质量标准限量(0.05 mg/L)要求,且低于同位素稀释-GC-MS的检出限(3.2 μg/L)。本方法可以满足地质调查及环境评价的需求。

     

    Abstract: 1,4-dioxane is toxic, easily entering the ecological system to cause damage of the environment and people health. It is relatively strong affinity for water, and not easy to be biodegradable in the natural environment. 1,4-dioxane is a new type of organic contaminants in groundwater, has been defined as one of the controlled substances by World Health Organization (WTO). But only few countries defined the limited value of 1,4-dioxane content in groundwater, as Japan is 50 μg/L. In China, this research field is rarely concerned, and there is none report for detection method of 1,4-dioxane in groundwater either. Purge and Trap-Gas Chromatography/Mass Spectrometry(P&T-GC/MS) is a fast, simple analytical method with low detection limit, in recent years it has been widely used in water analysis. This paper chooses P&T-GC/MS for the determination of trace 1,4-dioxane in groundwater. In the experiment, ammonium sulfate was added as sample protective agent to increase the sample storage time and prevent the deterioration from microbial degradation and other factors, but also improve the efficiency of the purge desorption for 1,4-dioxane, the instrument response value increased by one times. Under the optimized operating conditions of the instrument, the precision is 5.9%-6.6%; the detection limit is 1.02 μg/L, has been reached WHO standard for drinking water quality limit (0.05 mg/L), and is lower than the isotope dilution-GC-MS detection limit of 3.2 μg/L. This method can meet the demands during geological investigation and environmental assessment.

     

/

返回文章
返回