中文核心期刊

中国科技核心期刊

CSCD来源期刊

DOAJ 收录

Scopus 收录

程志中, 刘妹, 张勤, 顾铁新, 黄宏库. 水系沉积物标准物质研制[J]. 岩矿测试, 2011, 30(6): 714-722.
引用本文: 程志中, 刘妹, 张勤, 顾铁新, 黄宏库. 水系沉积物标准物质研制[J]. 岩矿测试, 2011, 30(6): 714-722.
CHENG Zhi-zhong, LIU Mei, ZHANG Qin, GU Tie-xin, HUANG Hong-ku. Preparation of Geochemical Reference Materials of Stream Sediments[J]. Rock and Mineral Analysis, 2011, 30(6): 714-722.
Citation: CHENG Zhi-zhong, LIU Mei, ZHANG Qin, GU Tie-xin, HUANG Hong-ku. Preparation of Geochemical Reference Materials of Stream Sediments[J]. Rock and Mineral Analysis, 2011, 30(6): 714-722.

水系沉积物标准物质研制

Preparation of Geochemical Reference Materials of Stream Sediments

  • 摘要: 为满足区域地球化学调查及矿产勘查的需要,新研制了15个水系沉积物标准物质,其中6个样品是原有水系沉积物标准物质的复制,9个新研制的样品主要采自中国北方的森林沼泽和干旱荒漠特殊景观区。样品粒度依据区域地球化学调查规范的要求,森林沼泽区采样粒级为2.0~0.22 mm,干旱荒漠区采样粒级为4.76~0.90 mm,山区和丘陵地区的采样粒级为小于0.22 mm。样品在室内晾干后在110℃烘24 h,置于大型高铝瓷球磨机粉碎并混匀,使样品中小于0.074 mm的部分大于99%以上。样品采用波长色散X射线荧光光谱进行进行均匀性检验,方差检验的F值小于临界值,所有元素的RSD均小于4%,大部分元素的RSD小于3%,P、Mn、Ti、Fe2O3、K2O等元素的RSD小于1%,证明样品均匀性良好。经2年内4次分析,检验结果表明对所检验的元素和成分均未发现统计学意义的明显变化,证明样品的稳定性良好。采用多家家实验室用不同原理的方法联合定值,邀请全国15家有资质的实验室采用准确度较高的方法分析测试约72种组分,根据ISO导则35和国家一级标准物质研制规范的要求,计算15种水系沉积物标准物质中72种元素和组分的标准值(部分组分给出参考值)和不确定度,这些新研制的标准物质是原有水系沉积物标准物质的一个补充。

     

    Abstract: In order to meet the needs of regional geochemical survey and mineral exploration, 15 reference materials of stream sediment were prepared as 6 of total 15 were duplicates for previous reference materials, 9 were new developed reference materials sampled from special landscape of forest, swamp and desert on northern China. Based on the requirements of regional geochemical survey, the size fractions for samples from froest-swamp, desert and mountain-hillyground area were 2.0-0.22 mm, 4.76-0.90 mm and less than 0.22 mm, respectively. The samples were heated in oven at 110 ℃ for 24 h after being dried down at lab. Then, the samples were crushed and the 99% final sizes were less than 0.074 mm by large-scale high Al porcelain ball mill. The good homogeneous was tested by wavelength dispersion X-ray fluorescence spectrum with F values were less than the critical value and RSDs were less than 4%. The RSDs of most elements were less than 3% and that of P, Mn, Ti, Fe2O3 and K2O were less than 1%.The stability was tested by 4 times analysis during 2 years and there was no significant change for all results. Fifteen certified laboratories in China participated to analysis about 72 components by suing high precision analytical method based on ISO guideline 35 and guideline for national first grade reference material preparation. The certified values(some were reference values) and RSD were presented for 72 components for 15 stream sediments reference materials. The new prepared geochemical reference materials enhanced greatly the previous system of stream sediments reference materials.

     

/

返回文章
返回