中文核心期刊

中国科技核心期刊

CSCD来源期刊

DOAJ 收录

Scopus 收录

胡志中, 李佩, 蒋璐蔓, 王通洋, 杜谷, 杨波. 古代玻璃材料LA-ICP-MS组分分析及产源研究[J]. 岩矿测试, 2020, 39(4): 505-514. DOI: 10.15898/j.cnki.11-2131/td.201909210134
引用本文: 胡志中, 李佩, 蒋璐蔓, 王通洋, 杜谷, 杨波. 古代玻璃材料LA-ICP-MS组分分析及产源研究[J]. 岩矿测试, 2020, 39(4): 505-514. DOI: 10.15898/j.cnki.11-2131/td.201909210134
HU Zhi-zhong, LI Pei, JIANG Lu-man, WANG Tong-yang, DU Gu, YANG Bo. Application of LA-ICP-MS in the Analysis of Archaeological Glass and Source Discrimination[J]. Rock and Mineral Analysis, 2020, 39(4): 505-514. DOI: 10.15898/j.cnki.11-2131/td.201909210134
Citation: HU Zhi-zhong, LI Pei, JIANG Lu-man, WANG Tong-yang, DU Gu, YANG Bo. Application of LA-ICP-MS in the Analysis of Archaeological Glass and Source Discrimination[J]. Rock and Mineral Analysis, 2020, 39(4): 505-514. DOI: 10.15898/j.cnki.11-2131/td.201909210134

古代玻璃材料LA-ICP-MS组分分析及产源研究

Application of LA-ICP-MS in the Analysis of Archaeological Glass and Source Discrimination

  • 摘要: 古代玻璃及玻璃质材料的定量分析对于研究其制作年代及产地、原料的来源以及制作工艺有着重要的参考意义。与电子探针(EMPA)、能谱扫描-电子显微镜(EDX-SEM)等分析方法相比,LA-ICP-MS能够快速且准确地提供样品主次量及微量元素信息。本文对LA-ICP-MS古代玻璃元素定量分析中的影响因素进行研究认为:在193nm激光下玻璃标准NIST610和康宁玻璃标准之间基体差异造成的影响较小,而采用玻璃标准NIST610为外标结合基体归一化法的校正策略测定康宁标准结果表明,该策略能够准确反映不同类型古代玻璃材料中成分组成;实验中不同剥蚀模式的研究,有助于不同实验条件的建立,从而满足不同研究的需要。本次研究对出土样品进行了分析,为该制品的产源研究提供了数据支持。

     

    Abstract:
    BACKGROUNDQuantitative analysis of ancient glass and vitreous materials has important significance for studying its production time, origin, source of raw materials and production process. Compared with traditional analysis methods (eg. EMPA, EDX-SEM), LA-ICP-MS can be used to analyze the primary, minor and trace elements in samples quickly and accurately.
    OBJECTIVESTo investigate the composition of archaeological glass and discriminate its sources.
    METHODSThe element concentration in ancient glass and vitreous materials were determined by LA-ICP-MS. The surface morphologies of pits in glasses were displayed by AFM.
    RESULTSThe matrix effect among NIST610 and Corning A-D was insignificant under 193nm laser system and this experimental condition. A quantification strategy based on NIST610 and normalization to 100% (w/w) was suitable for analyzing Corning A-D and ancient glass samples. Study on different ablation modes in the experiment is helpful for the establishment of different experimental conditions to meet the requirement of different studies.
    CONCLUSIONSUnearthed samples were analyzed, which provided data support for the source of the product.

     

/